Phoenix Contact – ESSENTIAL-PS/3AC/24DC/240W/EE – Power supply – 1018291
Primary-switched ESSENTIAL edition power supply for DIN rail mounting, input: 3-phase, output: 24 V DC / 240 W
Technical data
Input data
AC operation
|
Nominal input voltage range |
2x / 3x 400 V AC … 500 V AC |
|
Input voltage range |
3x 320 V AC … 575 V AC |
|
Input voltage range AC |
3x 320 V AC … 575 V AC |
|
2x 360 V AC … 575 V AC (for 2-phase operation) |
|
|
Voltage type of supply voltage |
AC |
|
Inrush current |
< 15 A |
|
Inrush current integral (I2t) |
0.2 A2s |
|
AC frequency range |
45 Hz … 65 Hz |
|
Mains buffering time |
> 20 ms (3x 400 V AC) |
|
Current consumption |
3x 0.6 A (400 V AC) |
|
3x 0.5 A (480 V AC) |
|
|
Nominal power consumption |
284.4 VA |
|
Protective circuit |
Transient surge protection; Varistor |
|
Power factor (cos phi) |
0.59 |
|
Typical response time |
< 1 s |
|
Permissible backup fuse |
B6 B10 B16 |
|
Recommended breaker for input protection |
6 A … 16 A |
|
Discharge current to PE |
< 3.5 mA |
Output data
|
Efficiency |
88.5 % (at 400 V AC and nominal values) |
|
Output characteristic |
U/I |
|
Nominal output voltage |
24 V DC ±1 % |
|
Setting range of the output voltage (USet) |
22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
|
Nominal output current (IN) |
10 A (UOUT= 24 V DC) |
|
Derating |
55 °C … 70 °C (2.5 %/K) |
|
Feedback voltage resistance |
35 V DC |
|
Protection against overvoltage at the output (OVP) |
< 35 V DC |
|
Max. capacitive load |
unlimited |
|
Active current limitation |
approx. 15 A |
|
Control deviation |
< 1 % (change in load, static 10 % … 90 %) |
|
< 2 % (change in load, dynamic 10 % … 90 %) |
|
|
< 0.1 % (change in input voltage ±10 %) |
|
|
Residual ripple |
< 10 mVPP |
|
Short-circuit-proof |
yes |
|
Output power |
240 W |
|
Peak switching voltages nominal load |
< 30 mVPP |
|
Maximum no-load power dissipation |
7.5 W |
|
Power loss nominal load max. |
34 W |
|
Rise time |
< 2 ms (UOUT(10 % … 90 %)) |
|
Connection in parallel |
yes, for redundancy and increased capacity |
|
Connection in series |
yes |
Connection data
Input
|
Connection method |
Screw connection |
|
Conductor cross section, rigid min. |
0.2 mm² |
|
Conductor cross section, rigid max. |
2.5 mm² |
|
Conductor cross section flexible min. |
0.2 mm² |
|
Conductor cross section flexible max. |
2.5 mm² |
|
Conductor cross section AWG min. |
24 |
|
Conductor cross section AWG max. |
14 |
|
Stripping length |
9 mm |
|
Screw thread |
M2,5 |
|
Tightening torque, min |
0.4 Nm |
|
Tightening torque max |
0.5 Nm |
Output
|
Connection method |
Screw connection |
|
Conductor cross section, rigid min. |
0.2 mm² |
|
Conductor cross section, rigid max. |
2.5 mm² |
|
Conductor cross section flexible min. |
0.2 mm² |
|
Conductor cross section flexible max. |
2.5 mm² |
|
Conductor cross section AWG min. |
16 |
|
Conductor cross section AWG max. |
12 |
|
Stripping length |
9 mm |
|
Screw thread |
M2,5 |
|
Tightening torque, min |
0.4 Nm |
|
Tightening torque max |
0.5 Nm |
Signaling
|
Types of signaling |
LED |
|
Operating voltage display |
Green LED |
Signal output
|
Status display |
"DC OK" LED green |
|
Note on status display |
UOUT> 21.5 V: LED lights up |
Electrical properties
|
Number of phases |
3 |
|
Insulation voltage input/output |
3 kV AC (type test) |
|
1.5 kV AC (routine test) |
|
|
Insulation voltage output / PE |
500 V DC |
Product properties
|
Product type |
Power supply |
|
Product family |
ESSENTIAL POWER |
|
MTBF (IEC 61709, SN 29500) |
> 700000 h |
Insulation characteristics
|
Protection class |
I (with PE connection) |
|
Overvoltage category |
III |
|
Degree of pollution |
2 |
Dimensions
|
Dimensional drawing |
![]() |
|
Width |
60 mm |
|
Height |
130 mm |
|
Depth |
152.5 mm |
Installation dimensions
|
Installation distance right/left |
0 mm / 0 mm |
|
Installation distance top/bottom |
50 mm / 50 mm |
Mounting
|
Mounting type |
DIN rail mounting |
|
With protective coating |
no |
Material specifications
|
Housing material |
Metal |
Environmental and real-life conditions
Ambient conditions
|
Degree of protection |
IP20 |
|
Ambient temperature (operation) |
-25 °C … 70 °C (> 55 °C Derating: 2.5 %/K) |
|
Ambient temperature (storage/transport) |
-40 °C … 85 °C |
|
Climatic class |
3K3 (in acc. with EN 60721) |
|
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
|
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
|
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz … 150 Hz, 2.3g, 90 min. |
Standards and regulations
|
Standard – Electrical safety |
EN 60950-1 |
|
Standard – Safety extra-low voltage |
EN 60950-1 (SELV) |
|
Approval – requirement of the semiconductor industry with regard to mains voltage dips |
SEMI F47 – 0706 (200 V AC) |
Approvals
|
CSA |
CSA-C22.2 Nr. 107.1-01 |
|
CSA-C22.2 Nr. 60950-01 |
|
|
UL approvals |
UL/C-UL listed UL 508 |
Conformity/Approvals
|
SIL in accordance with IEC 61508 |
0 |
|
Performance level according to ISO 13849 |
without |
EMC data
|
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
|
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
|
EMC requirements for noise emission |
EN 61000-6-3 |
|
EN 61000-6-4 |
|
|
EMC requirements for noise immunity |
EN 61000-6-1 |
|
EN 61000-6-2 |
Noise emission
|
Standards/regulations |
EN 55011 (EN 55022) Class B |
Electrostatic discharge
|
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge
|
Contact discharge |
8 kV (Test Level 4) |
|
Discharge in air |
8 kV (Test Level 3) |
|
Comments |
Criterion A |
Electromagnetic HF field
|
Standards/regulations |
EN 61000-4-3 |
Electromagnetic HF field
|
Frequency range |
80 MHz … 1 GHz |
|
Test field strength |
10 V/m |
|
Frequency range |
1 GHz … 2 GHz |
|
Test field strength |
10 V/m |
|
Frequency range |
2 GHz … 3 GHz |
|
Test field strength |
10 V/m |
|
Comments |
Criterion A |
Fast transients (burst)
|
Standards/regulations |
EN 61000-4-4 |
Fast transients (burst)
|
Input |
4 kV (Test Level 4 – asymmetrical) |
|
Output |
4 kV (Test Level 4 – asymmetrical) |
|
Signal |
2 kV (Test Level 3 – asymmetrical) |
|
Comments |
Criterion A |
Surge voltage load (surge)
|
Standards/regulations |
EN 61000-4-5 |
Surge voltage load (surge)
|
Input |
2 kV (Test Level 3 – symmetrical) |
|
4 kV (Test Level 4 – asymmetrical) |
|
|
Output |
1 kV (Test Level 2 – symmetrical) |
|
2 kV (Test Level 3 – asymmetrical) |
|
|
Comments |
Criterion A |
Conducted interference
|
Standards/regulations |
EN 61000-4-6 |
Conducted interference
|
Frequency range |
0.15 MHz … 80 MHz |
|
Comments |
Criterion A |
|
Voltage |
10 V (Test Level 3) |
Voltage dips
|
Standards/regulations |
EN 61000-4-11 |
Emitted interference
|
Standards/regulations |
EN 61000-6-3 |
|
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
|
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
|
Criterion A |
Normal operating behavior within the specified limits. |
|
Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial data
|
Item number |
1018291 |
|
Packing unit |
1 pc |
|
Minimum order quantity |
1 pc |
|
Sales key |
CMP |
|
Product key |
CMB333 |
|
GTIN |
4055626502632 |
|
Weight per piece (including packing) |
1,500 g |
|
Weight per piece (excluding packing) |
1,464 g |
|
Customs tariff number |
85044095 |
|
Country of origin |
CN |
Related products
-
Quick View
Morbi mattis ipsum sem
$33.00Add to cartin gravida dolor venenatis vestibulum. Aenean laoreet, nisi in bibendum dictum, purus libero accumsan enim, id vehicula enim metus vitae ipsum. Maecenas nulla est, dictum quis augue ultrices, dictum rutrum enim. Aliquam erat volutpat. Quisque ultricies ornare lacus, eu sagittis urna euismod ac. Nulla rhoncus ultrices ligula, id maximus ligula ultricies non.
-
Quick View
Fusce nec diam et dolor
$45.00Add to cartFusce nec diam et dolor ornare rhoncus nec ut mauris. In eleifend mi in felis dictum fermentum. Morbi vel arcu sit amet dolor venenatis bibendum in eu dui. Nulla velit dolor, imperdiet consectetur luctus ut, faucibus eget est.
-
Quick View
Nunc tempus facilisis
$87.00Add to cartFusce ullamcorper dapibus eleifend. Nullam ornare pulvinar lacinia. Nunc tempus facilisis ullamcorper. Nam sit amet suscipit risus, ut ultricies felis. Vivamus a finibus nisi. Sed quam sem, accumsan eget tristique sit amet, suscipit sit amet augue. Duis dolor dui, sagittis at faucibus ac, varius et sapien.
-
Quick View
Pellentesque dignissim sapien semper
$78.00Add to cartCras luctus ultricies ex luctus malesuada. Fusce imperdiet interdum consectetur. Pellentesque dignissim sapien semper consequat sollicitudin. Phasellus iaculis libero ac placerat aliquam. Etiam a velit eu diam consequat vestibulum. Ut a malesuada nulla. Vivamus quis maximus nisi, vel molestie sapien. Nunc pharetra finibus elit sed consectetur.






Reviews
There are no reviews yet.