PCB Electronic Circuit Board Laminating Production Line
Function And Performance
1. Reliable Quality And Technology
2. Lower Power Consumption
3. Outstanding Performance
4. Ensure The Precision Of Equipment
5. Automatic Error Detecting System
|
Press Type |
HDI 320 |
HDI 400 |
HDI 450 |
HDI 500 |
|
Number Of Daylights |
4/6/8/10/12 |
4/6/8/10/12 |
4/6/8/10/12 |
4/6/8/10/12 |
|
Pressure Range Press Surface |
40-850 KN |
60-1546 KN |
70-2177 KN |
90-2657 KN |
|
8,800-220,000 pds |
13,200-330,000 pds |
15,400-440,000 pds |
19,800-550,000 pds |
|
|
Useful Surface Specific Pressure Onto Useful Surface |
750 x600 mm |
750 x 850 mm |
750 x 1050 mm |
750 x 1150 mm |
|
750 x600 mm |
29.5 x 33.5" |
29.5 x 41.3" |
29.5 x 45.3" |
|
|
Distance Between Daylights Vacuum |
700×550 mm |
700 x 800 mm |
700 x1000 mm |
700 x 1100 mm |
|
27.6" x 21.7" |
27.6" x 31.5" |
27.6" x 39.4" |
27.6" x 43.3" |
|
|
Operating Temperature, Max. Heating / Cooling Media |
221 N/cm* |
276 N/cm² |
311 N/cm? |
345 N/cm? |
|
320 psi |
400 psi |
450 psi |
500 psi |
|
|
Other Sizes Available On Request Press Type |
75/ 100 mm |
75/ 100 mm |
75/ 100 mm |
75/ 100 mm |
|
2.95"/ 3.94" |
2.95"1 3.94" |
2.95"/ 3.94" |
2.95"1 3.94" |
|
|
Number Of Daylights Pressure Range |
< 10 mbar |
< 10 mbar |
< 10 mbar |
< 10 mbar |
|
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
|
|
Press Surface Useful Surface |
250°C/300°C |
250*C/300℃C |
250°C/300℃C |
250°C/300*C |
|
482-F/572 ℉ |
482-F/572°F |
482°F/572°F |
482°F/572°F |
|
|
Specific Pressure Onto Useful Surface |
Thermal oil |
Thermal oil |
Thermal oil |
Thermal oil |
|
Distance Between Daylights |
√ |
√ |
√ |
√ |
|
Press Type |
FL 280 |
FL 300 |
FL 350 |
FL 400 |
|
Number Of Daylights |
4/6/8/10/12 |
4/6/8/10/12 |
4/6/8/10/12 |
4/6/8/10/12 |
|
Pressure Range Press Surface |
40-745 KN |
60-1250 KN |
70-1850 KN |
90-2180 KN |
|
8,800-220,000 pds |
13,200-330,000 pds |
15,400-440,000 pds |
19,800-550.000 pds |
|
|
Useful Surface Specific Pressure Onto Useful Surface |
750 x 600 mm |
750 x850 mm |
750 x 1050 mm |
750 x 1150 mm |
|
29.5 x 23.6 " |
29.5 x 33.5" |
29.5 x 41.3" |
29.5 x 45.3" |
|
|
Distance Between Daylights Vacuum |
700 x 550 mm |
700 x 800 mm |
700 x 1000 mm |
700 x 1100 mm |
|
27.6" x 21.7" |
27.6" x 31.5" |
27.6" x 39.4" |
27.6" x 43.3" |
|
|
Operating Temperature, Max. Heating / Cooling Media |
193 N/cm2 |
221 N/cm2 |
263 N/cm2 |
311 N/cm2 |
|
280psi |
320 psi |
380 psi |
450 psi |
|
|
Other Sizes Available On Request Press Type |
75/ 100 mm |
75/ 100 mm |
75 / 100 mm |
75 / 100 mm |
|
2.95"/ 3.94" |
2.95"/ 3.94" |
2.95"1 3.94" |
2.95"1 3.94" |
|
|
Number Of Daylights Pressure Range |
< 10 mbar |
< 10 mbar |
< 10 mbar |
< 10 mbar |
|
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
|
|
Press Surface Useful Surface |
250°C/300C |
250°C /300°C |
250°C/300°C |
250°C/300°C |
|
482°F/572°F |
482°F/572°F |
482°F/572°F |
482°F/572°F |
|
|
Specific Pressure Onto Useful Surface |
Thermal oil |
Thermal oil |
Thermal oil |
Thermal oil |
|
Distance Between Daylights |
√ |
√ |
√ |
√ |
|
Press Type |
HT 100 |
HT 250 |
HT 300 |
HT 400 |
|
Number Of Daylights |
214/6/8 |
4/6/8/10 |
4/6/8/10 |
6/8//10/12 |
|
Pressure Range Press Surface |
40-1000 KN |
90-2500 KN |
100-3000 KN |
200-4000 KN |
|
8,800-220,000 pds |
19,800-550,000 pds |
22,000-660,000 pds |
44,000-880,000 pds |
|
|
Useful Surface Specific Pressure Onto Useful Surface |
750 x 600 mm |
750 x750 mm |
900 x 1000 mm |
750 x 700 mm |
|
29.5 x 23.6 " |
29.5 x 29.5" |
35.4 x 39.4" |
29.5 x 27.6" |
|
|
Distance Between Daylights Vacuum |
700 x 550 mm |
700 x 700 mm |
850 x 950 mm |
700 x 650 mm |
|
27.6" x 21.7" |
27 .6" x 27.6" |
33.5" x 37.4" |
27.6" x 25.6" |
|
|
Operating Temperature, Max. Heating / Cooling Media |
260 N/cm? |
740 N/cm? |
334 N/cm* |
879 N/cm* |
|
377 psi |
415 psi |
484 psi |
1275 psi |
|
|
Other Sizes Available On Request Press Type |
7 5/ 100 mm |
100 mm |
100 mm |
120 mm |
|
2.95"/ 3.94" |
3.94" |
3.94" |
4.72" |
|
|
Number Of Daylights Pressure Range |
< 10 mbar |
< 10 mbar |
<10 mbar |
< 10 mbar |
|
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
< 29.7 HG GAUGE |
|
|
Press Surface Useful Surface |
385°C |
385℃ |
385℃ |
385C |
|
725°F |
725°F |
725°F |
725°F |
|
|
Specific Pressure Onto Useful Surface |
Thermal oil |
Thermal oil |
Thermal oil |
Thermal oil |
|
Distance Between Daylights |
√ |
√ |
√ |
√ |
Related products
-
Quick View
OPTIMIZING CROSS CUT SAW MAXCUT F18S+SENSIT 005
Contact UsHigh speed optimization Timber cutting optimizing Cross-cut saw and precision cutting
Automation production line. -
Quick View
LFQ1300 Micro Computer Controlling Slitting Machine
Contact UsLFQ1300 Micro Computer Controlling Slitting Machine
-
Quick View
FS-V-F240 Injection valve
Contact UsFS-V-F240 series drip-proof valve is suitable for direct injection of lithium battery which can efficiently avoid liquid dropping and hanging.
-
Quick View
UT 1.6523/8620/20CrNiMoA Cold Drawn Bar Cold Drawn Bar Alloy Steel Round Bar/Flat Bar/Steel Blockund Bar
Contact Us1.6523 Cold Drawn Bar Cold Drawn Bar Alloy Steel Round Bar/Flat Bar/Steel Block/Round Bar






Reviews